(1) If a mortar is used for firing aerial shells—
(a) the mortar must be suitable for the purpose; and
(b) the mortar must be effectively stabilised to prevent adjacent mortars from being realigned during firing or because of any shell malfunctioning; and
(c) if the shells are greater than 150mm in diameter—
(i) the mortar must, if practicable, be buried to at least 2/3 of its length either in the ground, or in a container of sand; or
(ii) if it is not practicable to do so—any part of the mortar above ground must be surrounded with bags of sand to a width of at least 0.5m in all directions; and
(d) the mortar must otherwise be used in accordance with the requirements of AS 2187.4.
Note See AS 2187.4, s 4.4.2.
(2) A mortar must not be reloaded during the conduct of a fireworks display.
(3) A metal mortar must not be used for firing fireworks.