(1) A non-adjustable lighter must comply with subregulation (2) after being tested in accordance with the procedures described in schedule 1, parts 1.3, 1.4 and 1.5 .
(2) After the lighter has produced a flame for 10 seconds, the flame produced must extinguish after cessation of the action sustaining the flame within 2 seconds if the lighter has no flameguard or 4 seconds if it has a flameguard.
(3) An adjustable lighter must comply with subregulation (4) after being tested in accordance with the procedures described in schedule 1, parts 1.3, 1.4 and 1.5.
(4) After the lighter has produced a flame for 5 seconds at the maximum flame height adjustment, or a flame for 10 seconds at the minimum flame height adjustment, the flame produced must extinguish after cessation of the action sustaining the flame within 2 seconds if the lighter has no flameguard or 4 seconds if it has a flameguard.