(1) An application for a storage licence must include the following information and documents:
(a) the name and address of the applicant;
(b) the address of the premises where the explosives are to be stored;
(c) documentation describing a safety management system (including an emergency plan) for the storage of explosives at the premises;
(d) a scale plan of the premises showing the defined details;
(e) a description of each magazine to be used to store explosives, including the type of magazine as described in AS 2187.1;
(f) drawings and specifications showing construction details of each magazine;
(g) details of applicable separation distances enabling compliance with regulation 135 (Separation distances for magazines) to be established;
(h) for each kind of explosive to be stored in each magazine—
(i) the product name, UN number and classification code; or
(ii) the authorisation number;
(i) the maximum quantity of each kind of explosive to be stored in each magazine;
(j) the purpose of storage;
(k) the product name, UN number, classification code, packaging group and maximum quantity for each kind of dangerous substance (other than explosives) to be stored on the premises;
(l) for any external magazine (whether portable, relocatable or permanent) details of the following:
(i) any mounding;
(ii) any lightning protection;
(iii) any fencing;
(m) details of signage for each magazine and any fencing or building in which the magazine is contained;
(n) details of security arrangements;
(o) any other information or documents required by a form for the application approved under the Act, section 222.
(2) In this regulation:
"defined details", for a scale plan of the premises where the explosives are to be stored, means the following:
(a) the boundaries of the premises and the nature of any fencing;
(b) the location of all buildings and structures on the premises and their uses, including details of quantities of explosives and any other dangerous substances that may be present there;
(c) the location of each magazine or other storage facility for explosives and other dangerous substances;
(d) details of applicable separation distances for explosives and dangerous substances;
(e) any protected works within the separation distances;
(f) the location of services and utilities, including generation or distribution areas, and underground pipes and infrastructure;
(g) details of all internal roads and points of entry into, and exit from, the premises;
(h) the locations of all fire protection devices, including any automatic fire-sprinkler systems, fire hydrants, fire hose reels and portable fire-extinguishers.